Deterministic 6-Step Clinical Interoperability Pipeline

Consent-enforced clinical handoffs built to HIPAA requirements

Ten transfers. Four go through. Six are refused.

The refusals are the product. Anyone can move a file.

Katalyst reads the source record in place and routes an encrypted, time-limited bundle through six deterministic steps: 1. Identity, 2. Consent, 3. Translation, 4. Gate, 5. Chart, and 6. Timer. Katalyst keeps no clinical data after delivery. Signed audit and consent records are retained for 6 years.

Originating FacilitySource EHR (HL7 v2 / C-CDA / FHIR)
K
KatalystSteps 1–6 + Signed Audit Log
Receiving FacilityClinician Review → Destination Chart

Six-Step Pipeline Explorer (Steps 1–6)

Select any of the 6 sequential steps below to inspect inputs, outputs, and regulatory boundaries.

Step 1: Identity Resolution

Patient MPI matching & organization NPI / mTLS attestation

  • Resolves the patient across both organizations before anything else runs
  • Attests the requesting provider (Type 1 NPI) and organization (Type 2 NPI + TLS 1.3 cert)
  • Fails closed on an ambiguous patient match — it never guesses
Sample data flow
patientReyes, Maria · DOB 1974-03-12 · MRN 44821
requesterDr. A. Osei · NPI 1487203915 · Riverbend Hospital
matchresolved · deterministic MPI match verified
Data in
  • Requesting provider credential (NPI)
  • Patient demographics (Name, DOB, MRN)
  • Organization mTLS certificate
Data out
  • Signed identity assertion
  • Deterministic match verification
Touches
  • Demographics
  • Provider directory (NPPES)
  • Certificate chain
Never touches
  • Clinical records
  • Labs, meds, notes, imaging

Continuous Cross-Cutting Layer: Signed Audit Log

Hash-chained, Ed25519-signed decision log across all 6 steps (retained 6 years per HIPAA §164.316(b)(2)(i))

  • Appends a hash-chained, signed entry for every state transition across Steps 1–6
  • Contains zero clinical payload (PHI) — records actor NPIs, organization IDs, consent receipt IDs, and cryptographic hashes
  • Verifies the 7 self-auditing checks, including Check 7 (no AI code mapping suggestion reaches a chart without human clinician/HIM acceptance)

Step-by-Step Clinical & Security Specifications (Steps 1–6)

Step 1 of 6

Step 1: Identity Resolution

Patient MPI matching & organization NPI / mTLS attestation

  • Resolves the patient across both organizations before anything else runs
  • Attests the requesting provider (Type 1 NPI) and organization (Type 2 NPI + TLS 1.3 cert)
  • Fails closed on an ambiguous patient match — it never guesses
Step 2 of 6

Step 2: Consent Verification

Live query against the Katalyst consent-of-record ledger

  • Queries the Katalyst consent-of-record ledger live at request time — never from cache (US Core STU 9 defines no FHIR Consent profile, making the Katalyst consent-of-record ledger the Phase 1 source of truth)
  • Validates authorized categories, purpose of use, and revocation status before any translation occurs
  • Treats an absent or expired consent record as an immediate refusal (mapped to 45 CFR §171.202 Privacy Exception)
Step 3 of 6

Step 3: Clinical Translation

Normalizes HL7 v2, C-CDA, or vendor FHIR to a canonical Katalyst FHIR R4 profile

  • Normalizes HL7 v2, C-CDA, or vendor FHIR to a canonical Katalyst FHIR R4 profile in memory
  • Standard vocabularies (LOINC, SNOMED CT, RxNorm) are maintained by Katalyst Operations; unmapped local codes halt for Customer HIM / clinician approval (Check 7)
  • Encrypts the bundle at creation (AES-256-GCM) with its provider-set TTL stamped on
Step 4 of 6

Step 4: Security & Restriction Gate

Enforces 45 CFR §164.522(a) restrictions & cryptographic seal

  • Applies restrictions the source provider has agreed to honor (45 CFR §164.522(a)) and redacts restricted elements
  • Cryptographically seals the canonical FHIR R4 bundle and stamps its TTL expiration
  • Re-verifies consent revocation status at the outbound transit boundary
Step 5 of 6

Step 5: Destination Chart Review & Delivery

Clinician review queue & idempotent destination EHR write confirmation

  • Receiving clinicians review and accept items before they file; nothing posts silently. Typical sandbox transfer completes in under 2 minutes
  • Uses idempotency keys so network retries never duplicate clinical resources in the receiving chart
  • Returns a cryptographic write confirmation to the pipeline — unconfirmed means failed
Step 6 of 6

Step 6: Transient Purge & Destruction Proof

Cryptographic erasure upon delivery or TTL expiry

  • Permanently destroys the transient clinical bundle and its encryption key material upon Chart confirmation or TTL expiry
  • If a crash occurs before Chart confirmation, the transient bundle is purged at TTL and the transfer fails closed, requiring a retry or re-authorization
  • Katalyst keeps no clinical data after delivery. Signed audit and consent records are retained for 6 years

Mid-Transfer Crash & Fail-Closed Recovery Guarantee

If a crash occurs before Chart confirmation, the transient bundle is purged at TTL and the transfer fails closed, requiring a retry or re-authorization. Because Step 5 (Chart) enforces idempotency keys and requires clinician review and acceptance before filing, partial or duplicate writes cannot silently post to the destination EHR.

TEFCA, Carequality, CommonWell & 45 CFR Part 171 Information Blocking Alignment

National query networks (TEFCA QHINs, Carequality, and CommonWell) solve broad document discovery ("find every chart where this patient has been seen"), but they typically return coarse C-CDA dumps without granular, per-referral patient restriction enforcement, clinician-in-the-loop terminology gating (Check 7), or provable transient payload destruction. Katalyst complements national networks as the consent-enforced specialty handoff & redaction layer.

45 CFR §171.202 — Privacy Exception

Under the ONC Cures Act Final Rule, declining to fulfill an EHI request is not Information Blocking when a patient has not provided required consent or has requested a restriction that the source provider has agreed to honor under 45 CFR §164.522(a). Every consent refusal or category redaction in Katalyst logs the exact §171.202 sub-condition in the signed audit log.

45 CFR §171.203 — Security Exception

Halting a transfer due to an unverified organization certificate, ambiguous patient identity match, or failed cryptographic signature check is protected under the 45 CFR §171.203 Security Exception (directly related to safeguarding the confidentiality, integrity, and availability of EHI under tailored organizational policies).

Katalyst keeps no clinical data after delivery. Signed audit and consent records are retained for 6 years.Try the Interactive Demo