What your EHR or ASC needs to connect
Katalyst reads your record in place (via FHIR R4 for health systems or HL7 v2 MLLP / C-CDA R2.1 for ASCs and specialty practices) and shares an encrypted, consent-scoped copy that expires on its own. Here is everything required to stand that up, how we map to TEFCA / Carequality and ONC 45 CFR Part 171, and how we verify every credential before a single byte of PHI moves.
Hospital InfoSec teams can download our completed Shared Assessments SIG Lite, HECVAT, HIPAA Security Rule crosswalk, and standard BAA template upfront to accelerate vendor risk review.
While the technical sandbox handshake can be completed in a single working session, typical hospital go-live takes 6–10 weeks (subject to EHR vendor program approval, InfoSec review, and BAA execution): Weeks 1–2 BAA & SIG Lite review · Weeks 3–5 EHR Client/MLLP provisioning · Weeks 6–8 Sandbox & Clinical Reconciliation validation · Weeks 9–10 Production go-live.
Onboarding Readiness
0 of 17 complete (0%)
Check items off as your IT and Privacy teams confirm them. Progress is saved on this device.
Technical, Clinical & Regulatory Requirements
1. Connectivity (FHIR R4 + HL7 v2 MLLP & C-CDA)
Where Katalyst reads from and writes to inside hospital EHRs, ASCs, and specialty practices.
2. Identity, Patient Matching & TEFCA / Carequality Alignment
How we prove who is asking, who the record belongs to, and how national networks coexist.
3. Consent Source of Truth, ONC Part 171 & Governance
The regulatory architecture and legal agreements that govern every transfer.
4. People & 6–10 Week Go-Live Governance
Who we work with during onboarding and the realistic timeline to production.
Ambulatory Surgery Centers (ASCs) and specialty clinics without FHIR R4 servers connect via MLLP over TLS 1.3 (ADT/ORU/SIU/MDM) or C-CDA R2.1. Step 3 (Translation) converts segments to FHIR R4 only after Step 2 (Consent) succeeds.
Compatible with TEFCA QHINs and Carequality frameworks. Katalyst adds patient-directed category restrictions (45 CFR §164.522(a)), live mid-transfer revocation at the Gate boundary, and cryptographic destruction after delivery.
Refusals are never arbitrary information blocking: consent refusals cite 45 CFR §171.202 (Privacy Exception) and unverified endpoint/certificate refusals cite 45 CFR §171.203 (Security Exception) in the signed audit log.
How credentials are verified (6 Mandatory Gate Checks)
Six checks run in order. Each check below specifies expected inputs, expected outputs, pass criteria, and an interactive sandbox verification test. Any failure stops onboarding.
Each provider organization and requesting clinician is verified against the CMS NPPES registry, Direct Trust anchor bundle, and institutional SSO domain. Free-mail domains are rejected.
Type 2 Organization NPI + Type 1 Clinician NPIs + Institutional DNS TXT / SAML metadata
Verified Organization & Practitioner directory entries bound to pinned TLS client certificates
100% of registered NPIs active in NPPES; institutional domain ownership proven; free-mail domains blocked.
Provider identity attested
Katalyst publishes a dedicated JWKS endpoint and X.509 mTLS certificate thumbprint; your EHR or MLLP gateway registers our public key against our client_id. We sign a short-lived RFC 7523 JWT assertion (60s exp) per request — no shared secrets or static API keys ever exist.
Katalyst JWKS URI (RS384/ES384 public keys) + Client X.509 Certificate SHA-256 Thumbprint
OAuth 2.0 client_credentials access token issued via RFC 7523 private_key_jwt over mTLS 1.3
Valid JWT assertion accepted (<200ms); expired JWT, wrong audience, or unpinned TLS certificate rejected with HTTP 401/403 (ONC §171.203).
Asymmetric credentials & mTLS pin in place
We execute a read-only query against your sandbox (or receive a synthetic HL7 v2 ORU_R01 / C-CDA R2.1 document from an ASC/specialty site) for a synthetic test patient and validate resource mapping, terminology validation, and reconciliation queue routing.
Synthetic Patient MPI query + US Core FHIR R4 bundle (or HL7 v2.5.1 MLLP / C-CDA R2.1 payload)
18 validated FHIR R4 resources; discrete Meds/Problems/Allergies routed to Reconciliation Queue; unmapped local code held in Terminology Review Queue
End-to-end sandbox round-trip within 15–45s SLA; zero silent field drops; unmapped local codes held with Incomplete Record Warning.
Connectivity & clinical reconciliation routing confirmed
Three synthetic transfers are executed against the Katalyst Consent-of-Record Ledger: (a) consent absent, (b) 45 CFR §164.522(a) category restriction (Encounter Notes withheld, Labs/Meds allowed), and (c) live revocation mid-transfer before Step 4 (Gate).
3 synthetic transfer requests testing (1) No Consent, (2) §164.522(a) Withheld Notes, (3) Mid-Flight Revocation at T+1.8s
Case 1 halts at Step 2; Case 2 strips Encounter Notes at Step 4; Case 3 halts at Step 4 live Gate re-check and purges buffer
Zero unauthorized bytes egress in all 3 cases; ONC 45 CFR §171.202 Privacy Exception logged on refusals; Ed25519 audit chain intact.
Fail-closed Consent & Gate re-verification proven
A synthetic transfer is issued with a compressed 10-second TTL (simulating the 24–72h standard window and 60-minute Break-Glass window). Once the timer elapses, we attempt to re-read the transient copy and verify key destruction.
Encrypted transient bundle with ephemeral AES-256-GCM DEK + post-expiry read attempt
HTTP 410 Gone on post-expiry read; cryptographic destruction receipt (sha256 content + key purge fingerprint) written to signed audit log
Ephemeral DEK zeroized in KMS/memory within <1s of TTL expiry; zero residual PHI in cache, object storage, or backups (HIPAA §164.310(d)(2)(i)).
Time limits & cryptographic destruction enforced
With the BAA executed, SIG Lite / HECVAT approved by InfoSec, and Checks 1–5 green, credentials are promoted to production endpoints with automated 90-day JWKS key rotation and live SIEM webhook streaming.
Signed BAA + InfoSec sign-off + Green verification receipts from Checks 1–5 + SIEM Webhook URL
Production client_id activated; automated 90-day JWKS rotation scheduled; real-time SIEM AuditEvent stream live
All 7 self-auditing invariants pass in production smoke test; Privacy Officer & 24/7 escalation alerts verified.
Live in Production
Ready to start onboarding?
Bring the checked items above to complete a technical sandbox handshake in a single session (typical full production rollout: 6–10 weeks including EHR vendor & InfoSec sign-off).